DL8780
- Firmware
- Not recorded
- Test platform
- macOS
Checked against a live Philips DL8780. Other scales that speak the same Lifesense A2/A3 protocol may work, but are not all tested.
Scale / PROTOCOL LIBRARY
4 indexed models · 1 hardware verified
An open connection to Lifesense A2/A3 scales, including the Philips DL8780. Read measurements, understand the handshake, and use the library in your own application.
Catalog from openble · Updated · Source 13d75ea
ONE PROTOCOL, MANY DEVICES
Verification is specific to a model and the functions described below. Documented models still need a compatibility check.
Showing 4 models
Checked against a live Philips DL8780. Other scales that speak the same Lifesense A2/A3 protocol may work, but are not all tested.
Listed in the app’s scale model map. Live compatibility with this library has not been verified.
Listed in the app’s scale model map. Live compatibility with this library has not been verified.
Listed in the app’s scale model map. Live compatibility with this library has not been verified.
No models match these filters. Try another model or choose all statuses.
Add another model| Capability | Status | Details |
|---|---|---|
| Weight | Read | Parsers for A2 and A3 weight notifications. |
| Impedance | Read | Decode the scale’s measurement and append packets. |
| Pairing and sync | Available | A reusable handshake with persistent pairing state. |
| Bathroom Hub | Integrated | Assign readings to people and keep them on your own hardware. |
Checked against a live Philips DL8780. Other scales that speak the same Lifesense A2/A3 protocol may work, but are not all tested.
Body composition values in the Bathroom Hub are calculated per person. They are estimates, not medical measurements.
Run the Bathroom Hub, or use the library with your own Bluetooth transport.
pip install openble-lifesensefrom openble.lifesense.packets import parse_a3_weight
reading = parse_a3_weight(bytes.fromhex(
"1f 16 26 00 fe 89 50 91 1f 00 00 00 00 17 13 00 ff 01 19 00"
))
print(reading["weight_kg"]) # 97.5No linked open issues in this catalog update.
View protocol issuesAnother model, a better capture, or a missing detail can move the protocol forward.